Fundamentals of HVAC Systems Explained
Sep 11, 2024
🤓
Take quiz
🃏
Review flashcards
HVAC System Basics Lecture
Understanding Pressure and Temperature Relationships
Pressure and temperature are interrelated in HVAC systems.
Outside air must always be cooler than the refrigerant to allow for proper heat exchange.
Pressure can be manipulated to change the temperature of the refrigerant.
State Changes in Refrigerants
Refrigerants undergo state changes (liquid to vapor) in the system.
High pressure keeps refrigerant in a liquid state.
Dropping pressure allows refrigerant to boil and convert to vapor.
Phases of Matter in HVAC
Liquid and vapor are the main states present in HVAC systems.
Freezing occurs with water (condensation), not refrigerant.
System Components and Their Functions
Compressor:
Compresses refrigerant.
Condenser:
Converts vapor to liquid by releasing heat.
Evaporator:
Converts liquid to vapor by absorbing heat.
Metering Device (TEV/TXV):
Controls refrigerant flow, drops pressure, and initiates phase change.
Phase Change and Heat Movement
Pressure changes affect the boiling and condensing points.
Lower pressure results in a lower boiling point (e.g., boiling water at room temperature under vacuum).
Phase changes move more heat energy than temperature changes alone.
Example: Elevation and Boiling Point
At higher elevations, water boils at a lower temperature due to decreased pressure (e.g., 208°F at 5,000 ft).
Importance of Saturation in Heat Exchange
Saturation is key to heat absorption and release.
Saturation temperature gives insight into the state of refrigerant (liquid or vapor).
System Lines and Pressure
Low Side (Suction Line):
Connects evaporator and compressor.
High Side (Liquid Line):
Connects condenser and metering device.
Expansion Line:
From metering device to evaporator.
Mini Splits vs. Traditional Systems
Mini splits have longer expansion lines, often insulated due to condensation risk.
Temperature and Pressure Diagnostics
Use PSI readings to determine saturation temperature in the evaporator.
35° deviation from indoor ambient temperature should be maintained.
High side saturation should be 13-20° above outdoor ambient temperature.
Practical Examples and Applications
Suction saturation should be 35° below indoor ambient for optimal performance.
Use PT charts and tools like Measure Quick for accurate diagnostics.
Summary
Understanding the principles of pressure, temperature, and state changes is crucial for diagnosing and optimizing HVAC systems.
Regular checks and balancing of pressures and temperatures ensure efficient system operation.
Additional Resources
:
HVAC School Podcast
HVACRschool.com
Community and learning opportunities through their mobile app and Facebook group.
📄