a tiny interesting device called an mcb protects you and your house from electrical mishaps this breaker saves you from two situations first short circuit and second overload conditions in a short circuit scenario the mcb trips in less than three milliseconds and isolates the internal connections let's see how this smart device detects current chaos so quickly and precisely a simple device called a fuse which has a low melting point wire was used for home protection in earlier days in both the fault conditions mentioned previously the current spikes up resulting in overheating and fusing the wire or breaking the circuit however every time the fuse would blow you had to manually replace it until you could do that good luck with the blackout this commonly occurring situation is why circuit breakers were invented the circuit breaker is an automatic on off mechanism that keeps one side of the wire moving and the other fixed during an electric fault if the circuit opens wide we are done with the mcb design after the fault ends simply manually turn it on before getting more into the mcb design a small note about the current direction an mcb gets activated in less than three milliseconds which is way lower than the half cycle time period of an alternating current so it is okay to show the current flow in a single direction throughout the analysis now the question is how does this system recognize the occurrence of an electric fault the answer is that it has sensing elements which activates a triggering mechanism let's first see how we can design a super quick triggering mechanism which opens wide a clever mechanism to achieve this objective is shown here this mechanism has a lever to which a rectangular ring is connected as shown the rectangular ring is connected by two springs and a central lever in this position both the springs are in a neutral state when the lever moves up the bottom spring compresses and the top spring expands the forces of both these springs are eventually transferred to the lever via the rectangular ring and this force will be in the upper direction as you can see the rectangular ring is initially at a negative offset to the center of the lever the torque produced by the force acting on the rectangular ring will be in the clockwise direction if you release the lever in this position this clockwise torque will bring the lever back to its initial position however if you push the lever farther up you notice anything peculiar about the offset distance it suddenly becomes positive which means that after a critical limit the torque will act on it in a counterclockwise direction when the mcb is on this will be the position of the lever the structure of the mcb will block the lever from rotating further counterclockwise now if an external trigger turns the lever slightly the torque on the lever suddenly becomes clockwise and the circuit opens wide quickly without the need of an external force here as the operator pushes the lever down you can see in ultra slow motion how the mechanism operates in practice after a small angle the lever generates its own torque and then there is no need to apply external force now the only question is how can we generate this small input trigger or input motion when a fault occurs the best answer is with an electromagnet this coil produces magnetic fields proportional in nature to the current passing through them as the current increases the magnetic field becomes stronger throughout the video note that in the case of a short circuit the current rises up to a thousand times in magnitude within milliseconds this result generates a very strong magnetic field an iron cylinder and pin is placed inside this electromagnet on a spring slightly offset from its center the strong magnetic field pulls the cylinder downward thus pushing the pin this tiny movement of the pin is the input trigger of the mechanism and it leads to opening the circuit as we discussed earlier you might be wondering in normal current flow why isn't this cylinder attracted down well the force in normal current flow is not high enough to overcome spring tension whereas short circuit current can go up to 10 to 100 times the normal current the force is quite high so the circuit trips the danger of fault is not over yet folks as soon as the contacts are opened the current doesn't just stop flowing the fault current is of large value and will lead to air discharge or current will flow through the air it is an amazing to watch and yet hazardous arc to extinguish the ark a component called an arc runner or arc chute is used the arc chute is an arrangement of parallel plates arranged at small intervals as the contacts separate the heavy fault current flowing as an arc triggers a huge temperature rise that can cause damage therefore this arc should be killed resistance increases with length and decreases with area here we need increased resistance of the current which passes through air which is why the distance between the contact points is kept high after the circuit opens since the air is hot this arc will be pushed up later the arc is divided into small chunks thus reducing its area with increased resistance the arc dies away at current zero now let's see how the mcb prevents the second type of fault and overload condition an overload happens if you find yourself using a number of appliances at once since all the appliances in our houses are connected in parallel such a scenario will lead to an increase in current this is another dangerous scenario which we need to prevent the current flow during a short circuit rises by 10 to 100 times the rated current but in overload it only rises two to five times you might think that use of a separate electromagnet with lesser operating rating may solve this issue but it won't let's see why the problem with this new coil for an overload condition is that it will get activated even if you simply start another electrical appliance fluorescent tubes for example carry an in-rush current during startup that maintains for about 10 milliseconds and then goes back to normal therefore using a lower rated electromagnet will cause the breaker to trip unnecessarily when you start electrical appliances a perfect choice to solve the overload condition is a bi-metallic strip this sensor is a bit slower and offsets inrush currents as it stays around for only 10 milliseconds however it trips the ncb when the overload current maintains for two seconds or more in a bi-metallic strip as the current rises heat causes the strip to bend slowly this occurrence pushes a c-shaped lever and thus the main lever down and it thereby opens the contacts the current value at which the bi-metallic strip should operate can be varied with this screw which is only adjusted by manufacturers we hope you have now developed a good understanding of a miniature breaker with this precisely designed device you are safe from electrical disasters apart from mcb we have other breaker types designed for different types of faults rcd elcb and mccb don't forget to support us thank you